Benefits
- For short range, simple measurements
- Easy to install and maintain
- Easy two-button programming
- PVDF transducer for chemical compatibility
- IP68 rated
Supplementary Components are designed to work with most types of instrumentation to provide enhanced functionality such as remote displays and remote monitoring solutions.
Don’t forget that the safest engineered level measurement solution includes switches for back-up, overfill, low level and dry run protection.
Detail
SITRANS LU150Range | 0.25 to 5 m (0.8 to 16.4 ft) |
Ambient temperature |
Standard: -30 to 60 °C (-22 to 140 °F) Metallic mounting: -20 to 60 °C (-4 to 140 °F) |
Communications or Outputs | 4 to 20 mA |
Approvals | CE, CSAUS/C |
Key Applications | Chemical storage vessels, filter beds, mud pits, liquid storage vessels, food applications |
SITRANS LU180
Range | 0.25 to 5 m (0.8 to 16.4 ft) |
Ambient temperature |
Standard: -40 to 60 °C (-40 to 140 °F) Metallic mounting: -20 to 60 °C (-4 to 140 °F) |
Communications or Outputs |
4 to 20 mA |
Approvals |
CSA: IS/ Class I, II, III, Div. 1, Groups: A, B, C, D, E, F, G T4 FM: IS/ Class I, II, III, Div. 1, Groups: A, B, C, D, E, F, G T4 ATEX: II 1G Ex ia IIC T4 Ga IECEx Ex ia IIC T4 Ga NEPSI Ex ia II C T4 Ga |
Key Applications | Chemical storage vessels, filter beds, mud pits, liquid storage vessels, food applications |
4 to 20 mA
|