- Typical installations include ground or tank level monitoring of water and sewage treatment measurement
DESCRIPTION & FEATURES:
- Designed for continuous level measurement in water or other liquids with low viscosity
- 316L SS probe with stainless steel sensor for ease in cleaning
- Available ranges from H2O up to 300 psi
- ±0.1% to ±0.35% accuracy ratings
- NEMA 6P / IP68. Approved for outdoor use
- Customizable
- RoHS compliant
- 5 year warranty
SPECIFICATIONS
Output Signal |
Standard 2-wire: 4-20 mA / Vs = 8-32 Vdc Optional 3-wire: 0-20 mA / Vs = 14-30 Vdc 0-10 V / Vs = 14-36 Vdc |
Accuracy |
±0.35% FSO Optional nominal pressure ≥ 5 psi: <±0.25% FSO BFSL All nominal pressure: <±0.1% FSO BFSL |
Permissible Load |
Current 2-wire: Rmax = [(Vs – Vs min) / 0.02] Ohm Current 3-wire: Rmax = 500 Ohm Voltage 3-wire: Rmin = 10 kOhm |
Influence Effects |
Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
Long-term Stability | <±0.1% FSO/yr |
Response Time | ≤10ms* |
Permissible Temperatures |
Medium: 14°F to 158°F (-10°C to 70°C) Storage: -13°F to 158°F (-25°C to 70°C) |
Reverse Polarity Protection | No damage. No function. |
Electromagnetic Compatibility | Emission and immunity according to EN 61326 |
Electrical Connection | Cable with sheath material**: PVC grey, PUR black, FEP black, others available |
Pollution Degree | 4, electrical equipment for outdoor use |
Housing | 316L SS |
Seals | FKM, others available |
Diaphragm | 316L SS |
Weight | 200 g (without cable) |
Current Consumption |
Current: 25 mA max Voltage: 7 mA max |
Connecting Cables |
Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m |
Enclosure Rating | NEMA 6P / IP68 |