COSEL EAM-16
Quantity
Single-phase 250VAC¡¡16A
Low leakage current type Small-size
150£ëHz-1MHz
1-stage filter
Push down type terminal block
(2) Rated Current
(3) Line to ground capacitor code
Refer to Product Line-up.
* When the line to ground capacitor code is different, the attenuation characteristic is
different.
(4) Options
D:DIN rail installation type
* The dimensions change when the option is set. Refer to External view.
Low leakage current type Small-size
150£ëHz-1MHz
1-stage filter
Features of EAM-16
Small-sizePush down type terminal block
Ordering Information and Options
EAM(1) - 16(2) - 000(3) - ¡õ(4)
(1) Model Name(2) Rated Current
(3) Line to ground capacitor code
Refer to Product Line-up.
* When the line to ground capacitor code is different, the attenuation characteristic is
different.
(4) Options
D:DIN rail installation type
* The dimensions change when the option is set. Refer to External view.
Product Line-up
Product Name | Leakage Current* |
Line to ground capacitor (nominal value) |
---|---|---|
EAM-16-000 | 5μA/10μA max | Not Provided |
EAM-16-101 | 12.5μA/25μA max | 100pF |
EAM-16-221 | 25μA/50μA max | 220pF |
EAM-16-331 | 37.5μA/75μA max | 330pF |
EAM-16-471 | 50μA/100μA max | 470pF |
Specification
Contents | Specifications | |
---|---|---|
Rated Voltage | AC 1 φ 250V/DC250V | |
Rated Current | 16A | |
Operating Temperature | -40 to +85¡æ (Refer to Derating Curve) | |
Agency Approvals |
UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input) |
|
Others | Dimensions (WxHxD) |
39x30x85 mm [1.54x1.18x3.35 inches] (Option: -D refer to external view) |
Weight | 170g max | |
Warranty Period | 5-year |