COSEL Power Supply RBC300F
Quantity
Power & Electrical SuppliesPowerComputer Power SuppliesPower ConvertersSpecialty Electrical Switches & Relays
Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 300W
Slots: 3
Rated Output Voltage:
3.3V, 5V, 12V, 16.5V, 24V, 48V,
±12V, ±15V
・Multiple outputs combination (driving and control systems) for
robot controller applications
・Meets OVC¢ó (Complies with EN60204-1)
・Reinforced isolation between SLOT 3 and SLOT 1, 2
Please refer to Configuration-Model Name Construction in Instruction manual for Order Name.
Order Name is required to create by the above menu.
¡öModel Name
(2) Multiple output
(3) Output wattage
(4) Universal input
(5) Slot 3 Output module
(6) Slot 2 Output module
(7) Slot 1 Output module
(8) Optional
C : with Coating
G : Low leakage curent
R : with Remote ON/OFF
S : with Chassis
SN: with Chassis & cover
T : Vertical terminal block
Refer to instruction manual 9.1
*Empty slot is code: O (Alphabet )
Rated Output Wattage: 300W
Slots: 3
Rated Output Voltage:
3.3V, 5V, 12V, 16.5V, 24V, 48V,
±12V, ±15V
Features of RBC300F
・Configurable type power supply・Multiple outputs combination (driving and control systems) for
robot controller applications
・Meets OVC¢ó (Complies with EN60204-1)
・Reinforced isolation between SLOT 3 and SLOT 1, 2
Ordering Information and Options
The RB series has Order Name which is used for the ordering aside from Model Name.Please refer to Configuration-Model Name Construction in Instruction manual for Order Name.
Order Name is required to create by the above menu.
¡öModel Name
RB(1)C(2)¡¡300(3)¡¡F(4)¡¡-¡¡¡õ(5)¡õ(6)¡õ(7) -¡¡¡õ(8)
(1) Series name(2) Multiple output
(3) Output wattage
(4) Universal input
(5) Slot 3 Output module
(6) Slot 2 Output module
(7) Slot 1 Output module
(8) Optional
C : with Coating
G : Low leakage curent
R : with Remote ON/OFF
S : with Chassis
SN: with Chassis & cover
T : Vertical terminal block
Refer to instruction manual 9.1
*Empty slot is code: O (Alphabet )
Specification
Input Module
Contents | Specifications | ||
---|---|---|---|
Input Voltage | AC85 - 264V 1Φ | ||
Output | Number of Slot | 3 | |
Total Output power | AC90 - 264V | 303W | |
Operating Temperature/Humidity | -20 to +70¡æ, 20 - 90%RH (Non condensing) | ||
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No. 62368-1),¡¡EN62368-1, EN62477-1 (Overvoltage category ¢ó), Complies with EN61558-2-16 (Overvoltage category ¢ó) |
|
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR11-B, CISPR32-B, EN55011-B, EN55032-B | ||
High Attenuation | Complies with IEC61000-3-2 * | ||
Others | Dimensions (WxHxD) | 114x38.3x203mm [4.49x1.5x7.99 inches] | |
Weight | 710g max | ||
Cooling Method | Convection Cooling / Forced Air (Requires external fan) Cooling | ||
Warranty Period |
5-year |
Output Module
Slot1 240W Suitable Single Output
Contents | Specifications | |||
---|---|---|---|---|
Module Code | S | T | U | |
Number of Slots Used | 1 | 1 | 1 | |
Output | Wattage | 192W |
240W (Peak360W) |
240W (Peak360W) |
Voltage/Current | 12V 16A |
24V 10A (Peak15A) |
48V 5A (Peak7.5A) |
|
Adjustable Voltage Range |
11.40 ¡« 13.20V | 22.80 ¡« 26.40V | 45.60 ¡« 52.80V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating or 101% of peak current and recovers automatically. | ||
Overvoltage Protection | 14.40 ¡« 17.40V | 28.80 ¡« 34.80V | 57.60 ¡« 67.20V | |
Remote ON/OFF | Optional |
Slot2,3 15W Suitable Single Output
Contents | Specifications | |||
---|---|---|---|---|
Module Code | B | C | D | |
Number of Slots Used | 1 | 1 | 1 | |
Output | Wattage | 15W | 15.6W | 15.6W |
Voltage/Current | 5V 3A | 12V 1.3A | 24V 0.65A | |
Adjustable Voltage Range |
4.50 ¡« 5.50V | 10.80 ¡« 13.20V | 21.60 ¡« 26.40V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically. | ||
Overvoltage Protection | 5.75 ¡« 8.00V | 13.80 ¡« 19.20V | 28.80 ¡« 38.40V | |
Remote ON/OFF | Optional |
Slot2,3 30W Suitable Single Output
Contents | Specifications | ||||||
---|---|---|---|---|---|---|---|
Module Code | G | H | J | K | L | M | |
Number of Slots Used | 1 | 1 | 1 | 1 | 1 | 1 | |
Output | Wattage | 16.5W | 25W | 30W | 31.4W | 31.2W | 31.2W |
Voltage/Current |
3.3V 5A |
5V 5A |
12V 2.5A |
16.5V 1.9A |
24V 1.3A |
48V 0.65A |
|
Adjustable Voltage Range |
2.97 ¡« 3.63V | 4.50 ¡« 5.50V | 10.80 ¡« 13.20V | 14.85 ¡« 18.15V | 21.60 ¡« 26.40V | 43.20 ¡« 52.80V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically. | |||||
Overvoltage Protection | 4.00 ¡« 5.25V | 5.75 ¡« 7.00V | 13.80 ¡« 16.80V | 18.90 ¡« 23.10V | 28.80 ¡« 34.80V | 57.60 ¡« 67.20V | |
Remote ON/OFF | Optional |
Slot2 Dedicated Dual Output
Contents | Specifications | ||||
---|---|---|---|---|---|
Module Code | E | F | P | Q | |
Number of Slots Used | 1 | 1 | 1 | 1 | |
Output | Wattage | 14.4W | 15W | 16.8W | 21W |
Voltage/Current | ±12V 0.6A | ±15V 0.5A | ±12V 0.7A | ±15V 0.7A | |
Adjustable Voltage Range |
10.80 ¡« 13.20V | 13.50 ¡« 16.50V | 10.80 ¡« 13.20V | 13.50 ¡« 16.50V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically. | |||
Overvoltage Protection | 13.80 ¡« 19.20V | 17.25 ¡« 24.00V | 14.40 ¡« 18.00V | 18.00 ¡« 22.50V | |
Remote ON/OFF |
Optional |