TSURAGA MODEL 7562
Potentiometer Transducer
Isolated Potentiometer Transducer
Model Designation
7562 |
- |
¡õ |
- |
¡õ |
- |
¡õ |
|
|
¢Ù |
|
¢Ú |
|
¢Û |
-
Input:
-
Resistance of Potentiometer (100 Ω to 10 kΩ)
¢Ù Output Signal
Code |
Output Signal |
01 |
DC 0 to 10 mV |
02 |
DC 0 to 100 mV |
03 |
DC 0 to 1 V |
04 |
DC 0 to 5 V |
05 |
DC 0 to 10 V |
09 |
DC 1 to 5 V |
00 |
Except above DC voltage output
(10 mV to 10 V) |
13 |
DC ± 1 V |
14 |
DC ± 5 V |
10 |
Except above DC ±voltage output
(± 10 mV to ± 10 V) |
23 |
DC 0 to 1 mA |
29 |
DC 4 to 20 mA |
20 |
Except above DC current output
(100 µA to 20 mA) |
¢Ú Power Supply Voltage
Code |
Power Supply Voltage |
3 |
AC 100/110 V |
5 |
AC 200/220 V |
9 |
DC 24 V |
Input Specifications
Input |
Resistance of Potentiometer(100 Ω to 10 kΩ) |
Output Specifications
Output Signal |
Output Impedance |
Tolerable Load Resistance |
DC 0 to 10 mV |
Approx. 10 Ω |
More than 10 kΩ |
DC 0 to 100 mV |
Approx. 100 Ω |
More than 100 kΩ |
DC 0 to 1 V |
Less than 0.1 Ω |
More than 100 Ω |
DC 0 to 5 V |
More than 500 Ω |
DC 0 to 10 V |
More than 1 kΩ |
DC 1 to 5 V |
More than 500 Ω |
DC ±1 V |
DC ±5 V |
More than 2.5 kΩ |
DC ±10 V |
More than 5 kΩ |
DC 0 to 1 mA |
More than 5 MΩ |
0 to 12 kΩ
(During DC Power: 0 to 10 kΩ) |
DC 4 to 20 mA |
0 to 600 Ω
(During DC Power: 0 to 500 Ω) |
General Specifications
Input |
Resistance of Potentiometer(100 Ω to 10 kΩ) |
Input supply voltage |
0.5 V |
Allowance |
0.15% of SPAN at 23°C |
Response |
Less than 0.5s (0→90%) |
Temperature coefficient |
200 ppm/°C |
Output adjustment range |
ZERO£º 0 to 35% of input resistance
SPAN£º 50 to 100% of input resistance |
Insulation resistance |
Between input terminals and output terminals: DC 500 V¡¡More than 100 MΩ |
Withstand voltage |
-
Between input terminals and power supply terminals:
-
AC 1500 V 1min.(During DC Power: AC 1000 V 1min.)
-
Between input terminals and output terminals:
-
AC 1500 V 1min. (During DC Power: AC 1000 V 1min.)
Between all terminals and external case:AC 1500 V 1min. |
Power supply voltage |
AC 100/110 V ±10%¡¡50/60 Hz |
: |
Less than 3 VA |
AC 200/220 V ±10% 50/60 Hz |
: |
Less than 3 VA |
DC 24 V ±10% |
: |
Less than 70 mA |
|
Operating temperature |
-5 to 55°C |
Storage temperature |
-20 to 70°C |
Weight |
Approx. 400 g(AC) / Approx. 250 g(DC), Socket: Approx. 70 g |