TSURUGA MODEL 7541
AC Transducer
Isolated AC Voltage, AC Current Transducer
Model Designation
¢Ù Input Signal
Code |
Input |
43 |
AC 0 to 110 V¡¡* |
44 |
AC 0 to 150 V |
45 |
AC 0 to 220 V¡¡* |
53 |
AC 0 to 1 A |
54 |
AC 0 to 5 A |
-
*
-
Rated output will be obtained during AC 100/200 V input, 110% times rated output will be obtained during AC 110/220 V input.
¢Ú Output Signal
Code |
Output |
01 |
DC 0 to 10 mV |
02 |
DC 0 to 100 mV |
03 |
DC 0 to 1 V |
00 |
Except above DC voltage output (10mV to 5V) |
23 |
DC 0 to 1 mA |
Input Specifications
Input Signal |
Input Loss |
AC 0 to 110 V |
Less than 1 VA |
AC 0 to 150 V |
Less than 1 VA |
AC 0 to 220 V |
Less than 1.5 VA |
AC 0 to 1 A |
Less than 1 VA |
AC 0 to 5 A |
Less than 1 VA |
Output Specifications
Output Signal |
Output Impedance |
Tolerable Load Resistance |
DC 0 to 10 mV |
Approx. 10 Ω |
More than 10 kΩ |
DC 0 to 100 mV |
Approx. 100 Ω |
More than 100 kΩ |
DC 0 to 1 V |
Approx. 1 kΩ |
More than 1 MΩ |
DC 0 to 1 mA |
Approx. 6 kΩ |
0 to 5 kΩ(need to select) |
General Specifications
Allowance |
0.5% of SPAN at 23°C |
Response |
Less than 0.7s (0→99%) |
Output ripple |
Less than approx. 3% p-p of SPAN |
Temperature coefficient |
500 ppm/°C |
Output adjustment range |
ZERO£º¨D
SPAN£ºMore than ± 5% of SPAN |
Frequency |
50/60 Hz,¡¡400 Hz(need to select) |
Insulation resistance |
Between Input terminals and Output terminals: DC 500 V¡¡more than 100 MΩ (Voltage input is not isolated.) |
Withstand voltage |
-
Between Input terminals and Output terminals:
-
AC 2000 V¡¡1min.(Only current input)
-
Between all terminals and external case:
-
AC 2000 V¡¡1min.
|
Operating temperature |
-5 to 55°C |
Storage temperature |
-20 to 70°C |
Weight |
Approx. 230 g(Current input) / Approx. 160 g(Voltage input)
Socket£ºApprox. 70 g |