TSURUGA MODEL 452B
TSURUGA MODEL 452B Panel Meter Digital/Printer Tsuruga Malaysia, Penang, Butterworth Supplier, Suppliers, Supply, Supplies | TECH IMPRO AUTOMATION SOLUTION SDN BHD
Quantity
Tempurature Measuring Digital Meter Relay

  • ¡ö Easy recognition of judgement results using 2-color display
  • ¡ö Equipped with a second LED display for monitoring operating status trend
  • ¡ö Output of the 4-point Comparison decision for high-low and zone judge
  •  
  • Model Designation
  • 452B - ¡õ - ¡õ - ¡õ - ¡õ
        ¢Ù   ¢Ú   ¢Û   ¢Ü

    ¢ÙPower supply voltage

    Code Power source voltage
    A AC 100 to 240 V
    B DC 12 to 24 V
    C DC 110 V

    ¢ÚData output 1

    Code Data output Output impedance Tolerable Load resistive
    Blank -
    09 Analog output DC 0 to 10 V
    (Available scaling,Default: 1 to 5 V )
    Less than 0.1 Ω More than 500 Ω (DC 1 to 5 V)
    More than 1 kΩ (DC 0 to 10 V)
    29 Analog output DC 0 to 20 mA
    (Available scaling,Default: 4 to 20 mA)
    More than 5 MΩ 0 to 600 Ω (DC 4 to 20 mA)
    BP BCD output (TTL level positive logic) -
    BN BCD output (TTL level negative logic) -
    DP BCD output (transistor output, source type) -
    DN BCD output (transistor output, sink type) -
    E0 RS-232C -
    E1 RS-485 -

    ¢ÛData output 2
    (Available- 09 and -29 of ¢ÜData output 1 only)

    Code Data output
    Blank No output
    E0 RS-232C
    E1 RS-485

    ¢ÜComparison output

    Code specifications
    Blank Relay output
    TN Open collector output(NPN)

    Measuring Input

    Thermocouple
    Sensor Measuring range Display range Accuracy
    R 110.0 to 1700.0°C -50.0 to 1800°C ±(0.1% of rdg + 0.6digit) [100.0 to 500.0°C]
    ±(0.1% of rdg + 0.5digit) [500.0 to 1700.0°C]
    K -100.0 to 1300.0°C -200.0 to 1400.0°C ±(0.1% of rdg + 0.6digit) [-100.0 to 0.0°C]
    ±(0.1% of rdg + 0.5digit) [0.0 to 1300.0°C]
    E -130.0 to 1000.0°C -250.0 to 1050.0°C ±(0.1% of rdg + 0.5digit)
    J -140.0 to 1200.0°C -210.0 to 1250.0°C
    T -200.0 to 400.0°C -250.0 to 420.0°C
    B 600.0 to 1800.0°C -20.0 to 1820.0°C ±(0.1% of rdg + 0.6digit)
    N -100.0 to 1300.0°C -230.0 to 1350.0°C ±(0.1% of rdg + 0.5digit)
    Resistance thermobulb
    Sensor Measuring range Display range Accuracy
    Pt100Ω
    range[1]
    -200.0 to 850.0°C -200.0 to 870.0°C ±(0.1% of rdg + 0.2digit) [0.0 to 100.0°C]
    ±(0.2% of rdg + 0.3digit) [-200.0 to 0.0°C] [100.0 to 850.0°C]
    Pt100Ω
    range[2]
    -150.00 to 150.00°C -180.00 to 180.00°C ±(0.1% of rdg + 0.2digit) [0.0 to 100.0°C]
    ±(0.2% of rdg + 0.3digit) [-150.0 to 0.0°C] [100.0 to 150.0°C]
    JPt100Ω -200.0 to 645.0°C -200.0 to 660.0°C ±(0.1% of rdg + 0.2digit) [0.0 to 100.0°C]
    ±(0.2% of rdg + 0.3digit) [-200.0 to 0.0°C] [100.0 to 645.0°C]

    Basic Specifications

    Display 0 to 99999, red or green LED (character height 15.2 mm), “-” polarity, with zero-suppress function.
    Display color changes RR, RG, GR, GG (R: Red when any AL from 1 to 4 ON, G: Green when all AL turn OFF.)
    Sub-display 0 to 99999, red LED (character height 7.6 mm)
    Display method Hold display, data output, current value, peak memory, bottom memory, and display amplitude.
    Current value, PB 1 second, Memory, Peak memory, PM illuminates, Bottom memory, BM illuminates, Display amplitude
    Over-range display Flashing with minimum or maximum value of display range
    Resolution: RTD input 0.1 °C (0.01°C when PT100Ω range 2)
    Thermocouple input 0.1 °C
    External resistance 500Ω Max. for Thermocouple input
    Overload DC +/- 10V
    Sampling rate 200 ms
    Display cycle selectable from 200ms, 400ms, 1s, 2s, 4s, 5s
    Response within 2 samplings or within display cycle, whichever longer
    Input method Single ended, floating input
    A/D conversion ¨S-∑ conversion method
    Noise Rejection Normal mode (NMR) - More than 50 dB.
    Common mode (CMR) - More than 110 dB.
    Noise through power supply line – 1000 V (at AC voltage power supply)
    Insulation Resistance DC500V, More than 100 MΩ
    Withstand Voltage Input terminals - External case: AC 1500 V each for 1min.
    Power supply terminals - External case: AC 1500 V each for 1min.
    Power supply terminals - Input and output terminals: AC 500 V each for 1min.
    Input terminals - Output terminals: AC 500 V each for 1min.
    Power Supply AC 100 to 240 V (90 to 250 V) 50/60 Hz, DC 12 to 24 V (9 to 32 V)
    Power Consumption 452B itself: Approx. 9 VA at 100 V AC, 11.5 VA at 200 V AC, 400 mA at 12 V. 200 mA at 24 V DC.
    Operating Temperature 0 to 50°C
    Storage Temperature -20 to 70°C
    Weight Approx. 300 g
    Housing protection IP65 for the front panel, IP20 for the rear case, IP00 for terminals