TSURUGA MODEL 3153B
TSURUGA MODEL 3153B Panel Meter Digital/Printer Tsuruga Malaysia, Penang, Butterworth Supplier, Suppliers, Supply, Supplies | TECH IMPRO AUTOMATION SOLUTION SDN BHD
Quantity
DC Voltmeter/ Ammeter

  • ¡ö 45 mm character size clear bright large LED display.
  • ¡ö Equipped with scaling function.
  • ¡ö Available with average calculation, display hold, peak/bottom display function.
  • ¡ö AC power supply 100 to 240 V.
  •  
  • Model Designation
  • 3153B - ¡õ - A - ¡õ
        ¢Ù   ¢Ú   ¢Û

    ¢ÙMeasuring Input

    Code Measuring Range Input Resistance Accuracy *   Overload
    02 ±99.99 mV 100 MΩ ±(0.05% of rdg + 1 digit) DC ±250 V
    03 ±999.9 mV 10 MΩ ±(0.05% of rdg + 1 digit) DC ±250 V
    04 ±9.999 V 10 MΩ ±(0.1% of rdg + 1 digit) DC ±250 V
    05 ±99.99 V 10 MΩ ±(0.1% of rdg + 1 digit) DC ±500 V
    09 1 to 5 V 1 MΩ ±(0.1% of rdg + 1 digit) DC ±250 V
    13 ±999.9 µA 100 Ω ±(0.1% of rdg + 1 digit) DC ±50 mA
    14 ±9.999 mA 10 Ω ±(0.1% of rdg + 1 digit) DC ±150 mA
    15 ±99.99 mA 1 Ω ±(0.1% of rdg + 1 digit) DC ±500 mA
    16 ±999.9 mA 0.1 Ω ±(0.1% of rdg + 1 digit£© DC ±2 A
    19 4 to 20 mA 12.5 Ω ±(0.1% of rdg + 1 digit£© DC ±150 mA
       * Accuracy:
    Defined in the condition of 23 ± 5°C, 45 to75% RH.
         Temperature coefficient:
    ±150 ppm/°C, (operating temp. range: 0 to 50°C.

    ¢Ú Power Supply

    Code Power Source Voltage
    A AC 100 to 240 V

    ¢ÛDisplay Color

    Code Description
    R Red LED
    G Green LED

    General Specifications

    Display Red or green LED, character height 45 mm, with zero-suppress function.
    Display scaling Full scale display: -9999 to 9999
    Offset display: -9999 to 9999
    Offset fixing function The display for the value less than the offset value can be set to display the offset value.
    Decimal point Arbitrarily settable from the terminal blocks
    Over-range display When exceeded 100% or 130%, indicated with 
    When exceeded -100% or -130%, indicated with .
    Display cycle 67ms, 400ms, 1s, 2s, 3s, 4s, 5s Selection of setting available
    Average calculation Divisional averaging or moving average, and the numbers of samples for averaging can be selected.
    OFF: No moving averaging
    ON: Divisional averaging
    Numbers of sample for averaging, 2, 4, 8, 16, 32
    Hold function Holds measurement data (No isolation and measurement input)
    Peak / Bottom change-over Function of the terminal block P/B can be changed to maximum or minimum value display.
    100 digit turn out The display of 100 digit is compulsorily turn out.
    Power supply AC 100 to 240 V, 50/60 Hz
    Tolerance of source voltage AC 90 to 250 V
    Power consumption AC 100 V … Approx. 4 VA
    AC 200 V … Approx. 5 VA
    Operating temperature 0 to 50°C
    Operating humidity 35 to 85% RH¡¡£¨No condensation£©
    Storage temperature -20 to 70°C
    Insulation resistance DC 500 V¡¡ More than 50 MΩ
    Withstand voltage Between input terminal and external case: AC 1500 V for 1min.
    Between power supply terminals and external case: AC 1500 V for 1min.
    Between power supply terminals and input terminals: AC 1500 V for 1min.
    Weight Approx. 900 g
    Unit Indication Designated character is adhered at the right bottom of the front mask.
    (It has to be designated at the time of ordering.)
    Protection Degree Front side IP40, back side IP20

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf