TSURUGA Square shape Indicator for Model RD, RP series
Quantity
・Lineup with 4 types
・Easy-to-Read with clear indicator
・Variety of scale and unit availbale
・Easy installation
・Bright scale face with wide surface range
Specification
Specification
Model | T¡õRD-43 | T¡õRD-21 | T¡õRP-25 | TSRP-80AA | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Symbol of operating principles |
Each '¡õ' symbol is filled with operating principle below.
|
|||||||||||||
Standard Specification | Dimension | 43 x 43 mm | 60 x 60 mm | 80 x 80 mm | 82 x 82 mm | |||||||||
Weight (1 mA DC rated) |
0.04kg | 0.07kg | 0.12kg | 0.1kg (5A) | ||||||||||
Operating Principles |
|
AC : Moving Iron type | ||||||||||||
Accuracy Class | Class 2.5 | |||||||||||||
Length of Scale | 30 mm | 49 mm | 62 mm | 70 mm | ||||||||||
Shape of pointer | Black bar | |||||||||||||
Color of indicator panel | White | |||||||||||||
Color of cover | Transparent | Black | ||||||||||||
Test Voltage | Terminal/Outer case More than AC 2210 V 5sec. | |||||||||||||
Operating temperature | 0 to 40 ¡æ | |||||||||||||
Operating humidity | 30 to 90 %RH (No Condensing) |
40 to 75 %RH (No Condensing) |
||||||||||||
Standard Rated Input |
DC Ammeter (Moving coil) |
1 mA, 10 mA to 1 A |
100 μA, 500 μA, 1 mA | - | ||||||||||
10 mA to 10 A | 10 mA to 20 A | |||||||||||||
DC Voltmeter (Moving coil) |
1 to 150 V | 1 to 300 V | - | |||||||||||
Receiving meter (Moving coil) |
4 to 20 mA |
4 to 20 mA 1 to 5 V (4 kΩ) 1 to 5 V (1 MΩ, with Converter 7331) |
- | |||||||||||
AC Ammeter | Rectifier type | - | 1 mA to 10 mA | 1 mA to 300 mA | - | |||||||||
RMS effective value type | 1 A to 30 A (with external Coverter 7311) | - | ||||||||||||
Moving Iron type | - | 1 to 30 A | ||||||||||||
AC Voltmeter | Rectifier type | 10 V to 150 V | 10 to 300 V | - | ||||||||||
Moving Iron type | - |
¡òTwice or three times extended scale can be manufactured if AC Ammeter of RMS type and moving coil type of analog meter.
¡òWhen the rated value is exceeded in DC Ammeter, connect the shunt and analog meter with 60 mV rated value.
¡òWhen the rated value is exceeded in DC voltmeter, connect the multiplier and analog meter with 1 mA rated voltage.
¡òWhen the rated value is exceeded in AC Ammeter, connect the current transformer (CT) with analog meter with 5 A rated current.
¡òWhen the rated value is exceeded in AC voltmeter, connect voltage transformer (VT) and analog meter with 100 V rated voltage.
Customers are requested to provide the following information during order.
- 1. Model
- 2. Rated input value
- 3. Scale and Unit
- ¡ùReceiving meter of DC 1 to 5 V (1 MΩ£©needs power supply.