TSURUGA Wide angle round Indicator for Model TMW, TCW, TAW series
TSURUGA Wide angle round Indicator for Model TMW, TCW, TAW series Analog Meter Analog Instrument Tsuruga Malaysia, Penang, Butterworth Supplier, Suppliers, Supply, Supplies | TECH IMPRO AUTOMATION SOLUTION SDN BHD
Quantity
・Lineup with 3 types
・Easy-to-Read with large and clear indicator
・Variety of scale and unit availbale
・Easy installation
・Bright scale face with wide surface range

Specification
Model T¡õW-2C T¡õW-25 T¡õW-4B
Symbol of operating principles Each '¡õ' symbol is filled with operating principle below.
'M' : Moving Coil type
'C' : Rectifier type
'A' : RMS effective value type
'e.g. TMW-25 is a 80mm squre meter with moving coil.
Standard Specification Dimension 65 x 65mm 80 x 80 mm 110 x 110 mm
Weight
(1 mA DC rated)
0.20kg 0.24kg 0.72kg
Operating Principles
DC : Moving Coil type
AC : Rectifier type
  RMS effective value type
(for Ammeter more than 1A)
Accuracy Class Class 2.5 Class 1.5
Length of Scale 110 mm 136 mm 195 mm
Color of indicator panel White
Color of cover Black
Test Voltage Terminal/Outer case More than AC 2210 V 5sec.
Operating temperature 0 to 40 ¡æ
Operating humidity 30 to 90 %RH (No Condensing)
Standard Rated Input DC Ammeter
(Moving coil)
500 μA, 1 mA,
10 mA to 75 mA
500 μA,1 mA,
10 mA to 10 A
500 μA, 1 mA,
10 mA to 30 A
DC Voltmeter
(Moving coil)
1 V to 150 V 1 V to 300 V
Receiving meter
(Moving coil)
4 to 20 mA
1 to 5 V (4kΩ£©
1 to 5 V (1 MΩ, with external Converter 7331)
AC Ammeter Rectifier type 1 mA to 10 mA 1 mA to 300 mA
RMS effective value type 1 A to 30 A
(with external Coverter 7311)
1 A to 5 A
(with built-in CT)
10 A to 30 A
(with Converter 7311)
AC Voltmeter (Rectifier type) 10 V to 150 V 10 V to 300 V

¡òTwice or three times extended scale can be manufactured if AC Ammeter of RMS type and moving coil type of analog meter.
¡òW-2C, W-25 : When the rated value is exceeded in DC Ammeter, connect the shunt and analog meter with 100 mV rated value.
¡òW-4B : When the rated value is exceeded in DC Ammeter, connect the shunt and analog meter with 60 mV rated value.
¡òWhen the rated value is exceeded in DC voltmeter, connect the multiplier and analog meter with 1 mA rated voltage.
¡òWhen the rated value is exceeded in AC Ammeter, connect the current transformer (CT) with analog meter with 5 A rated current.
¡òWhen the rated value is exceeded in AC voltmeter, connect voltage transformer (VT) and analog meter with 100 V rated voltage.

Customers are requested to provide the following information during order.

  1. 1. Model
  2. 2. Rated input value
  3. 3. Scale and Unit
  4. ¡ùReceiving meter of DC 1 to 5 V (1 MΩ£©needs power supply.