Output:RS-485 / 0 … 10 V / 4 … 20 mA
RS-485:Digital output with Modbus RTU protocol, 0 ... 6000 PPM​
Measuring range:0 … 2,000 / 0 … 5,000 / 0 … 20,000 (PPM) (Max.:50,000 PPM)
Accuracy:±40 PPM±3% of reading(at 25°C)
IP rating:IP54(Clamp);IP65(Flange)

Description

  • Using patented state-of-the-art non-dispersive infrared(NDIR)wave-guide technology and offers reliable measurements
  • Comply to EMC directive 2014 / 30 / EU
  • CO2 Measuring range:0 … 2,000 / 0 … 5,000 / 0 … 20,000(PPM) (Max.:50,000 PPM);IP65 / IP54
  • Digital output(RS-485 Modbus RTU protocol, 0 ... 6000 PPM), analog output(0 … 10 V, 4 … 20 mA)
  • Maintenance-free in most HVAC ventilation applications
  • High tolerance to extreme humidity environment conditions
  • Non-frill design, direct DDC connection

eYc GS07 is a state-of-the-art non-dispersive infrared(NDIR)carbon dioxide(CO2 )transmitter. The direct insertion design and miniature size make it easy to install in the ventilation duct. eYc GS07 provides measurement in analog outputs(0 … 10 V, 4 … 20 mA)and digital output(RS-485 Modbus RTU protocol). With CO2 demand controlled ventilations, eYc GS07 helps to save money by decreasing the energy consumption while maintaining a healthier indoor climate

Specification

Measuring range:0 … 2,000 / 0 … 5,000 / 0 … 20,000 (PPM) (Max.:50,000 PPM)
Output:RS-485 / Voltage or current
RS-485:Digital output with Modbus RTU protocol, 0 ... 6000 PPM
Voltage or current signal terminal CO2
Operating temperature range:0 … 50°C
Storage temperature range:-40 … +70°C
Operating humidity range:0 … 100% RH(Sensor in powered-up condition)
Operating environment:Residential, commercial and industrial spaces
Warm-up time:≦1 min(at full specs≦15 min)
Sensor life expectancy:>15 years
Duct air velocity:Direct insertion sensor, no minimum airspeed requirement
Maintenance interval:No maintenance(with ABC algorithm)
Power input:AC / DC 24 V±20%, 50 Hz or 60Hz(Half-wave rectifier input)
Power consumption:<1 W average
Connection wires:M12 male connector for power input(G+, G0)& voltage / Current output(Out) with M12 female quick connection cable(AWG24 wires)
Sensing method:Non-dispersive infrared(NDIR)waveguide technology with Automatic Background 
Calibration(ABC)and passive gas diffusion(No moving parts)
Response time(T1/e):<10 sec(at 30 cc/min. flow rate) / <3 min diffusion time
Repeatability:±30 PPM±1% of reading
Accuracy:±40 PPM±3% of reading(at 25°C)
Annual zero drift:<±10 PPM(with ABC function)
Pressure dependence:+1.6% reading per hPa
Installation support:Background level calibration adjustment jumper trigger(bCAL)
Dimension:94x30 mm diameter
Installation method:Clamp or Flange
IP rating:P54(Clamp);IP65(Flange)
Compliance with EMC directive:2014 / 30 / EU