COSEL Power Supply Power Supply ACE650F
Quantity
Power & Electrical SuppliesPowerComputer Power SuppliesPower ConvertersSpecialty Electrical Switches & Relays
Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 650W
Slots: 5
Rated Output Voltage: 2V,3.3V,5V,7.5V,12V,15V,18V,24V,34V,48V,±5,±12,±15,±24,5V/5V,5V/12V,5V/24V
• Harmonic attenuator (Complies with IEC61000-3-2)
• Universal input (AC85-264V)
• Remote ON/OFF control, alarm
(2) Abbreviation power of ACE series
6: ACE650F(AC6)
(3) Slot 6 Output module
(4) Slot 5 Output module
(5) Slot 4 Output module
(6) Slot 3 Output module
(7) Slot 2 Output module
(8) Slot 1 Output module
(9) Parallel code
(10) Option (series code)
Refer to instruction manual 5.1
Safety: UL60601-1, EN60601-1
Refer to instruction manual.
*The number of slot is different depending on the model.
*Empty slot is code: 0
Rated Output Wattage: 650W
Slots: 5
Rated Output Voltage: 2V,3.3V,5V,7.5V,12V,15V,18V,24V,34V,48V,±5,±12,±15,±24,5V/5V,5V/12V,5V/24V
Features of ACE650F
• Flexible modular system architecture provides various output configuration• Harmonic attenuator (Complies with IEC61000-3-2)
• Universal input (AC85-264V)
• Remote ON/OFF control, alarm
Ordering Information and Options
AC(1) ¡õ(2) - ¡õ(3) ¡õ(4) ¡õ(5) ¡õ(6) ¡õ(7) ¡õ(8) - ¡õ¡õ(9) - ¡õ¡õ(10)
(1) Abbreviation type name of ACE series(2) Abbreviation power of ACE series
6: ACE650F(AC6)
(3) Slot 6 Output module
(4) Slot 5 Output module
(5) Slot 4 Output module
(6) Slot 3 Output module
(7) Slot 2 Output module
(8) Slot 1 Output module
(9) Parallel code
(10) Option (series code)
Refer to instruction manual 5.1
Safety: UL60601-1, EN60601-1
Refer to instruction manual.
*The number of slot is different depending on the model.
*Empty slot is code: 0
Specification
Input Module
Contents | Specifications | ||
---|---|---|---|
Input Voltage | AC85 - 264V 1Φ / DC120 - 350V * | ||
Output | Number of Slot | 5 | |
Total Output power | AC90 - 150V | 600W | |
AC170 - 264V | 650W | ||
Operating Temperature/Humidity | -20 to +70¡æ, 20 - 90%RH (Non condensing) | ||
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL60950-1, C-UL (CSA60950-1) , EN60950-1, EN50178, EN62368-1 Complies with DEN-AN (At only AC input) UL60601-1, EN60601-1 (At only AC input) (Refer to instruction manual 7) |
|
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B | ||
High Attenuation | Complies with IEC61000-3-2 * | ||
Others | Dimensions (WxHxD) | 127x63.5x279mm [5x2.5x10.98 inches] | |
Weight | 2.4kg max | ||
Cooling Method | Forced cooling (built-in) | ||
Warranty Period | 3-year |
Output Module
50W Suitable Single Output
Contents | Specifications | |||||
---|---|---|---|---|---|---|
Module Code | L | M | N | P | R | |
Number of Slots Used | 1 | 1 | 1 | 1 | 1 | |
Output | Wattage | 33W | 50W | 60W | 60W | 60W |
Voltage/Current | 3.3V 10A | 5V 10A | 12V 5A | 15V 4A | 24V 2.5A | |
Adjustable Voltage Range | 2.60 - 3.60V | 4.00 - 5.50V | 9.00 - 13.2V | 13.2 - 16.5V | 19.2 - 26.4V | |
Protection Circuit And Others |
Overcurrent Protection |
Works over 105%min of rated current. Automatic recovery.
|
||||
Overvoltage Protection | 4.00 - 5.25V | Works at 115 - 140% of rated voltage | ||||
Remote ON/OFF |
Available
|
|||||
Remote Sensing |
-
|
|||||
Others |
-
|
150W Suitable Single Output
300W Suitable Single Output
75W Dual Output
Contents | Specifications | ||||
---|---|---|---|---|---|
Module Code | Y | W | Z | 9 | |
Number of Slots Used | 1 | 1 | 1 | 1 | |
Output | Wattage* | 50W | 76.8W | 75W | 76.8W |
Voltage | ±5V | ±12V | ±15V | ±24V | |
Current1* | 3A | 3.2A | 2.5A | 1.6A | |
Current2* | 7A | 4.2A | 3.5A | 2.5A | |
Peak Current* | - | 5A | 4A | - | |
Adjustable Voltage Range | 4.99 - 6.00V | 9.60 - 13.2V | 13.2 - 16.5V | 19.2 - 26.4V | |
Protection Circuit And Others |
Overcurrent Protection |
Works over 105%min of rated current or 101%min of peak current. Automatic recovery.
|
|||
Overvoltage Protection | 6.90 - 8.40V | 13.8 - 16.8V | 17.25 - 21.0V | 27.6 - 33.6V | |
Remote ON/OFF |
Available
|
||||
Remote Sensing |
-
|
||||
Others |
-
|
150W Dual Output
Contents | Specifications | ||
---|---|---|---|
Module Code | Q | V | |
Number of Slots Used | 1 | 1 | |
Output | Wattage* | 153.6W | 165W |
Voltage | ±12V | ±15V | |
Current1* | 6.4A | 5.5A | |
Current2* | 8A | 7A | |
Peak Current* | 10A | 8A | |
Adjustable Voltage Range | 9.60 - 13.2V | 13.2 - 16.5V | |
Protection Circuit And Others | Overcurrent Protection |
Works over 105%min of rated current or 101%min of peak current. Automatic recovery.
|
|
Overvoltage Protection | Works at 115 - 140% of rated voltage | ||
Remote ON/OFF |
Available
|
||
Remote Sensing |
-
|
||
Others |
-
|
100W Insulation Dual Output
Contents | Specifications | ||||||
---|---|---|---|---|---|---|---|
Module Code | S | T | U | ||||
Number of Slots Used | 1 | 1 | 1 | ||||
Output | Wattage | 75W | 100.4W | 100.4W | |||
Voltage/Current |
V1: 5V 10A |
V2: 5V 5A |
V1: 5V 10A |
V2: 12V 4.2A |
V1: 5V 10A |
V2: 24V 2.1A |
|
Adjustable Voltage Range | 4.99 - 5.50V | 3.00 - 5.50V | 4.99 - 5.50V | 7.50 - 13.2V | 4.99 - 5.50V | 15.0 - 26.4V | |
Protection Circuit And Others | Overcurrent Protection |
Works over 105%min of rated current. Automatic recovery.
|
|||||
Overvoltage Protection |
Works at 115 - 140% of rated voltage
|
||||||
Remote ON/OFF |
Available
|
||||||
Remote Sensing |
-
|
||||||
Others |
-
|