TSURUGA MODEL 416M
Quantity
Thermocouple-Resistance Thermometer
- ¡ö DIN 72×36 mm compact size.
- ¡ö Compatible with various sensors.
- Model Designation
-
416M - ¡õ - ¡õ - ¡õ - ¡õ ¢Ù ¢Ú ¢Û ¢Ü ¢ÙInput
Thermocouple
Code Type *1 Measuring Range Display Range Accuracy *2 TC R 100 to 1700°C -50 to 1750°C ±(0.3% of rdg + 1°C) K -100 to 1300°C -199 to 1350°C E -130 to 1000°C -199 to 1050°C J -140 to 1200°C -199 to 1250°C T -199 to 400°C -199 to 420°C B 600 to 1800°C -20 to 1810°C N -100 to 1300°C -199 to 1350°C *1 There will be °C display of K type TC during shipment. *2 Accuracy : Defined in the measuring range, at 23 ± 5°C, 45 to 75% RH. Temperature coefficient : ±300 ppm/°C (operating temp.: 0 to 50°C) Cold junction compensation : ±1°C (operating temp.: 0 to 50°C) Calibration is made with standard thermo-electricity input (mV) in accordance with JIS C-1602. Resistance Thermometer
Code Type *3 Measuring Range Display Range Accuracy *4 PT Pt100Ω -199.9 to 600.0°C -199.9 to 650.0°C ±(0.2% ofrdg + 0.3°C) JPt100Ω *3 There will be Pt100Ω and °C setting display during shipment. *4 Accuracy : Defined in the measuring range, at 23 ± 5°C, 45 to 75% RH. Temperature coefficient : ±200 ppm/°C (operating temp.: 0 to 50°C) Calibration is made with standard resistance values in accordance with JIS C-1604. ¢ÛData Output
Code Specifications Output Impedance Allowable Load Resistance Blank For display only 03 Analog output ¡¡DC 0 to 1 V Less than 0.1 Ω More than 1 kΩ 04 Analog output ¡¡DC 0 to 5 V Less than 0.1 Ω More than 5 kΩ 05 Analog output ¡¡DC 0 to 10 V Less than 0.1 Ω More than 10 kΩ 09 Analog output ¡¡DC 1 to 5 V Less than 0.1 Ω More than 5 kΩ 23 Analog output ¡¡DC 0 to 1 mA More than 5 MΩ 0 to 5 kΩ 29 Analog output ¡¡DC 4 to 20 mA More than 5 MΩ 0 to 600 Ω General Specifications
Display Red or green LED (character height 15mm) with zero-suppress function. Mode display 1 digit, red or green LED (character height 8mm) Over-range display When exceeded the displayable range, the minimum or maximum value of the displayable range flashes. Open circuit of input Thermocouple input: Flashes with the minimum value of the display range.
Resistance thermo bulb input: Flashes with the maximum value of the display range.Resolution Thermocouple: 1°C
Resistance thermometer: 0.1°CExternal resistance Thermocouple: Less than 500 Ω
Resistance thermometer: Less than 5 Ω/lead wire.Overload DC ±10 V Sampling rate Approx. 2.5 times/s Input configuration Single ended, floating input A/D conversion ¨S-∑ conversion system Noise rejection Normal mode ¡¡(NMR): More than 50 dB
Common mode¡¡ (CMR): More than 110 dB
Power source line mixing noise: 1000 VHold function Holds measured data, peak/bottom memory value and data output (option).
(Not isolated from input)Peak/bottom memory function Display of maximum or minimum value is selectable with the front panel switch Withstand voltage Insulation resistance DC 500 V More than 100 MΩ Operating temperature 0 to 50°C Protection degree IP65 Weight Approx. 200 g