AC Voltmeter/ Ammeter

  • ¡ö RMS value calculation type.
  • ¡ö Full scale Display: 1000 to 9999 (optional setting).
  • ¡ö Power supply available with AC and DC
  •  
  • Model Designation
  • 482F - ¡õ - ¡õ - ¡õ - ¡õ - ¡õ
        ¢Ù   ¢Ú   ¢Û   ¢Ü   ¢Ý

    ¢ÙMeasuring Input

    Code Measuring Range Input Resistance Accuracy * Overload
    22 99.99 mV 10 MΩ ±(0.2% of rdg + 10 digit) AC 10 V
    23 999.9 mV 10 MΩ ±(0.2% of rdg + 10 digit) AC 100 V
    24 9.999 V 10 MΩ ±(0.2% of rdg + 10 digit) AC 700 V
    25 99.99 V 10M Ω ±(0.2% of rdg + 10 digit) AC 700 V
    26 699.9 V 10 MΩ ±(0.3% of rdg + 10 digit) AC 700 V
    32 99.99 µA 1 kΩ ±(0.5% of rdg + 10 digit) AC 10 mA
    33 999.9 µA 100 Ω ±(0.5% of rdg + 10 digit) AC 50 mA
    34 9.999 mA 10 Ω ±(0.5% of rdg + 10 digit) AC 150 mA
    35 99.99 mA 1 Ω ±(0.5% of rdg + 10 digit) AC 500 mA
    36 999.9 mA 0.2 Ω ±(0.7% of rdg + 10 digit) AC 2 A
    37 5.000 A 0.01 Ω ±(0.7% of rdg + 10 digit) AC 10 A
         *Accuracy:
    Defined at 23 ± 3oC, 45 to 75% RH.
    This definition is applied to the sine wave input of 5% or higher of the full scale.
          Frequency range:
    Sine wave of 40 Hz to 1 kHz
          Temperature coefficient:
    ±300 ppm/oC¡¡(Defined at 0 to 50oC)

    ¢ÚPower Supply

    Code Power Source Voltage
    3 AC 100 V
    5 AC 200 V
    9 DC 24 V

    ¢ÛData Output

    Code BCD Specifications
    Blank For display only
    BP TTL level (positive logic£©
    BN TTL level (negative logic£©
    DN transistor (sink type£©

    ¢ÜDecimal Point

    Code Description
    Blank Front setting
    1 External control

    ¢ÝDisplay Color

    Code Description
    Blank Red LED
    G Green LED

    General Specifications

    Display 0 to 9999 red or green LED (character height 14.2 mm) with zero-suppress function.
    Scaling function Full scale display 1000 to 9999.
    Decimal point Optional setting (front setting or external control).
    Over-range display Display becomes intermittent when exceeded 9999.
    Hold function Holds measurement data. (no isolation)
    Resolution 1/10000
    Sampling rate 2.5 to 0.2 times/s variable.
    Input type Single ended, floating input.
    A/D conversion Dual Slope Integration System
    Rectification system Effective value operation method.
    Noise rejection Power source line mixing noise¡¡1000 V
    Response to input Approx. 1s
    Crest factor 4 £¨482F-23: 3.5, 482F-26: Up to peak 1000 V, 482F-37: 2£©
    Withstand voltage
    Input terminal - external case AC 1500 V 1min.
    Power terminal - external case AC 1500 V 1min.
    Power terminal - Input terminal  AC 1500 V 1min.
    Insulation resistance DC 500 V, More than 100 MΩ
    Power supply AC 100 V£¨90 to 132 V£©
    AC 200 V£¨180 to 250 V£©
    DC 24 V£¨24 V ± 10%£©
    Power consumption AC power source… Approx. 3 VA
    DC power source… Approx. 60 mA
    Operating temperature 0 to 50°C
    Storage temperature -20 to 70°C
    Weight AC power source…Approx. 350 g
    DC power source…Approx. 250 g
    External imensions 96(W)×48(H)×89.5(D) mm